Products
Pumps
Pump Systems
Digital Solutions
Shredding Systems
Applications
Environmental Technology
Biogas Handling
Mining and Mineral Processing
Food and Beverage Industry
Oil, Gas and Petrochemicals
Pulp & Paper Industry
Additional Industries
Media
News
Fairs and Events
Downloads
Videos
Knowledge on Demand
SEEPEX Technologies
Security Publications
Services
SEEPEX Care Service Programs
Original Parts
Commissioning
24-Hour Helpline
Services
Company
About SEEPEX
Career
Locations
Build America, Buy America

Pump selection begins after the material behavior and transfer requirements are understood. The task is to convert representative concentrate data, the required withdrawal range, inlet conditions, and the installed pipeline into a pump configuration that can operate and be maintained under actual plant conditions.

 

A nominal solids percentage or maximum flow rate is not enough. The selected pump must establish flow after planned stoppages, deliver concentrate across the required operating range, and provide sufficient pressure without relying continuously on its maximum capability. Wear, controls, service access, and the downstream process are part of the same decision.

Build the Pump Specification from Representative Data

The duty data should cover normal production, the most difficult, anticipated material condition, and restart after a planned stoppage. Where ore types or operating campaigns change, the resulting range must remain visible rather than being reduced to one design point.

The specification should include solids concentration by mass or volume, slurry density, temperature, particle-size distribution, maximum particle size, mineralogy, and available rheological data. Yield stress and the flow curve should reflect relevant sample conditioning, including previous shear exposure and resting time.

Define the Required Withdrawal Range

Pump selection requires the minimum, normal, and maximum delivered flow. The normal operating point should remain within a practical speed range, while the minimum and maximum values define the required control window.

Positive-displacement pumping creates a controlled relationship between speed and theoretical output. Actual delivery still depends on inlet filling, differential pressure, wear, and concentrate condition. The required range should therefore be defined in terms of delivered flow rather than speed alone.

Separate Starting Pressure from Operating Pressure

The pump must be sized for both the higher pressure that may be required to restart settled or structurally rebuilt concentrate and the pressure needed during continuous transfer.

The operating duty must combine representative rheological data with the installed pipeline and downstream pressure. Maximum pump pressure is not the normal operating target, and additional capability should not be used to force concentrate through an unidentified restriction.

Verify the Inlet Conditions

Discharge pressure capability cannot compensate for an inlet arrangement that does not supply concentrate consistently. The equipment review must establish the vertical distance between the thickener outlet and pump, suction-line length and diameter, fittings, minimum available level, and the possibility of settled material in the connection.

The pump and inlet configuration must provide sufficient filling across the expected yield-stress range. Where concentrate does not flow freely, the installation may require a revised pump position, larger connection, shorter suction path, or another approved feeding arrangement.

These conditions should be reviewed before the layout is finalized. High suction capability supports difficult intake conditions, but it does not make pump performance independent of inlet geometry or concentrate behavior.

Include Wear in the Configuration and Service Plan

Abrasive duty affects rotor and stator selection, pump speed, pressure per stage, inspection frequency, spare-parts planning, and service access. Particle characteristics, operating hours, pressure, and material velocity should therefore form part of the application review.

No pump configuration eliminates wear. The selection must balance capacity, pressure, rotational speed, expected component wear, and maintenance frequency for the duty.

Prepare the Information Required for Final Selection

A complete application review should confirm the delivered flow range, normal and maximum solids concentration, density, temperature, particle data, representative rheology, expected resting time, available inlet conditions, pipeline configuration, downstream pressure, operating hours, controls, and available service space.

Where rheology or settling behavior remains uncertain, representative testing may be required before the equipment specification is finalized.

Matching Pump Technology to the Recovery Duty

The selected pump must translate the application data into a workable configuration. Required flow determines the pump size and speed range, while starting and operating pressure influence the number of stages and the permissible pressure per stage. Inlet conditions, rheology, and abrasive duty affect the remaining configuration choices.

SEEPEX BN progressive cavity pumps provide speed-adjustable, positive-displacement transfer for concentrated underflow. High suction capability supports difficult inlet conditions, while smooth, pulse-free and low-shear delivery provides controlled flow to the downstream process. The clear pumping passage does not rely on internal pump valves, and the pump does not require gland water.

The approved application range extends to solids content of up to 80%, conveying capacities up to 350 m³/h, and pressures up to 48 bar, depending on pump selection and application conditions.

Final selection requires a specific BN configuration for the concentrate, delivered-flow range, inlet arrangement, starting and operating pressure, pipeline, controls, and expected wear. The product range limits confirm feasibility only after those application requirements have been established.

Decide Whether Maintain in Place Is Required

Maintenance access should be treated as an installation requirement, not assessed after the pump layout has been finalized. The decision between a conventional BN arrangement and the BNM Maintain in Place configuration depends on how the pump will be inspected and serviced within the available plant space.

The BNM configuration is particularly relevant where removing connected pipework would extend the maintenance task or where surrounding equipment limits access to the rotor-side and drive-side components. Rotor Joint Access and Drive Joint Access provide dedicated service routes for these areas while allowing connected pipework to remain installed during the defined maintenance activities.

The equipment layout must preserve the clearances required to use those features. The application review should confirm the space needed for the sliding casing movement, rearward removal of the drive and coupling rod unit, lifting equipment, tools, and personnel. Structural steel, cable routes, foundations, or adjacent equipment must not obstruct the planned service path.

Maintain in Place reduces the amount of dismantling needed to reach relevant components, but it does not remove the need for isolation, depressurization, lifting arrangements, or approved maintenance procedures. The value of the BNM design therefore depends on whether the installation allows the maintenance concept to be used as intended.

Verify the Selected Duty

Before purchase, the material data, pipeline calculation, inlet arrangement, control range, and maintenance layout should be reviewed as one duty. This confirms that the selected pump can deliver the required flow at the calculated pressure, accommodate expected restart conditions, and operate across the required speed range.

The installation review should also preserve access for inspection, component removal, lifting, and safe isolation. For the BNM pump, the required clearances allow the Maintain in Place design, Rotor Joint Access, and Drive Joint Access to be used as intended.

With the correct configuration, SEEPEX BN progressive cavity pumps provide controlled, speed-adjustable transfer of high-solids concentrate without pump pulsation, internal pump valves, or gland water. Where maintenance access is critical, the BNM configuration extends these benefits by reducing the dismantling required for defined service tasks.

A pump selected around the complete duty does more than meet a nominal flow and pressure point. It keeps concentrated mineral value moving predictably while providing the control range and service access needed for long-term operation.

Read More About Thickener Underflow Recovery Solutions